Strain/Voltage Measurement Isolation Card CDV-46AS
Add to Wishlist
Conditioner cards for EDX-100A EDX-200A and EDX-5000A. EDX-5000A does not support CAN card CAN-41A.
Availability:
1 in stock
Contact for a quote.
Request for Quotationช่องทางการสั่งซื้ออื่น ๆ
ติดต่อทาง Line
@santatech
ติดต่อทางอีเมล์
santatech@gmail.com
ติดต่อทางโทรศัพท์
02-1013454
Description
The cards are for measuring strain, voltage, acceleration, and temperature. CAN data is supported. Isolated amplifier cards and carrier-wave amplifier cards also available for countermeasure against noise.
Specifications
| Measuring Targets |
Strain gages (Full-bridge system) Strain-gage transducers Voltage |
|---|---|
| Channels | 4 |
| Input Format |
Balanced differential input (Strain mode) Unbalanced input (Voltage mode) |
| Input Resistance |
Approx. 10 MΩ + 10 MΩ (Strain mode) Approx. 1 MΩ (Voltage mode) |
| IMRR | 120 dB (When 2k ×10-6 strain range) |
| Frequency Response |
[With DC coupling] DC to 5 kHz, deviation within +1 dB, -3 dB [DC cut (With AC coupling)] 0.2 Hz (See the HPF) |
| Gage Factor | 2.00 fixed (Strain mode) |
| Bridge Excitation | Within 2 VDC ±2% (Strain mode) |
| Compatible Bridge Resistance | 120 to 1000 Ω (Strain mode) |
| Measuring Range |
2k, 5k, 10k, 20k, 50k, 100k ×10-6 strain, OFF (At strain measurement) 1, 2, 5, 10, 20, 50, OFF (At voltage measurement) |
| Range Accuracy | Within ±0.3% FS |
| Balance Adjustment Range |
Within ±2.4% (±12000 ×10-6 strain) (At strain measurement) Within ±5 V (At voltage measurement) |
| ZERO Accuracy | Within ±0.3% FS (Voltage OFF mode) |
| Nonlinearity | Within ±0.1% FS |
| Calibration Values (CAL) |
Output at ±100% and ±50% of each range Accuracy: Within ±0.3% FS |
| LPF |
Transfer characteristic : 2nd order Butterworth Cutoff frequencies : 10, 30, 100, 300, 1 kHz and FLAT (6 steps) Amplitude ratio at cutoff point : -3 ±1 dB Attenuation : (-12 ±1) dB/oct. |
| HPF |
Cutoff frequencies : 0.2 Hz Attenuation : Within (-6 ±1) dB/oct. |
| AD Converter | 24 bits |
| Monitor Output | Accuracy: Within ±5 V ±0.5% (±5 V of full scale of each range) |
| Isolation |
Between input and case (output): Withstand voltage 500 VDC, 1 min. Between channels: Withstand voltage 500 VDC, 1 min. |
| TEDS | Reads information from TEDS-installed sensors. |
| Max. Sampling Frequency | 100 kHz |
| Standard Accessories | Conversion adapter FV-2A × 4 |
|---|