Universal Recorder EDX-200A-4T
Add to Wishlist
Incorporated real-time digital filter.8th digital filter enables acquisition of clear waveform.High-speed/low-speed dual samplingMeasurement of high-speed and low-speed phenomena while reducing data quantities is possible.
Availability:
1 in stock
Contact for a quote.
Request for Quotationช่องทางการสั่งซื้ออื่น ๆ



Description
The EDX-200A is a high-end Universal Recorder, which is as user-friendly as EDX-100A.
Various conditioner cards are available for wide applications.
Models |
EDX-200A-4T (With DCS-100A) EDX-200A-4T-0 EDX-200A-4T-1 (With DCS-100A and DCS-101A) |
---|---|
Measuring Targets |
Strain (Gage, transducer) Voltage Thermocouples Pulse (F/V) Piezoelectric acceleration (Built-in amplifier) CAN signals GPS |
Conditioner Cards for Analog Inputs |
The conditioner cards for EDX series [Note] The EDX-200A-4T can use only the CVM-41A,CDV-40B, CDV-40B-F and CAN-41A which performed temperature extension processing. [Note] The EDX-200A limits the number of CFV-40A. The number of CFV-40A is up to 2. |
Conditioner Cards for CAN Data Inputs |
CAN card (2 ports, max. 256 channels): CAN-41A [Note] Can install one CAN-41A to the final slot. |
Voice Memo Input |
1 channel (Input voice memo data is recorded together with the measurement data.) Use remote control unit RCU-42A. (Optional accessory) Use the Data Analysis Software DAS-200A (optional accessory) to play back recorded voice memos. |
Sampling
Sampling Method | Simultaneously all channels |
---|---|
Sampling Mode |
Normal: Records all channels' data at the same sampling clock. Dual: Enables high-speed sampling or low-speed sampling to every CH for recording. |
Sampling Frequencies
Normal-sampling Mode |
1-2-5 series 1 Hz to 100 kHz 1 Hz to 2 kHz When using CAN-41A 2n series 2 to 65536 Hz 2 to 2048 Hz When using CAN-41A |
---|---|
Dual-sampling Mode |
High-speed sampling [Sf] 1-2-5 series 1 Hz to 100 kHz 1 Hz to 2 kHz when using CAN-41A 2n series 2 to 65536 Hz 2 to 2048 Hz when using CAN-41A Low-speed sampling [Ss] 1-2-5 series The division frequencies from high-speed sampling, and Ss ≤ Sf/4 2n series The division frequencies from high-speed sampling, and Ss ≤ Sf/4 |
Channels
Normal-sampling Mode | Max. 32 channels, 320 k/I (I is the integer part of the set sampling frequency.) |
---|---|
Dual-sampling Mode | Max. 64 channels, 320 k/I (I is the integer part of the set sampling frequency.). “High-speed and low-speed” setting counts as 2 channels. |
When Using CAN-41A | Channels of CAN data |
The Number of Sampling Frequency
Normal Mode | “320000/ The number of channels” or less |
---|---|
Dual Mode |
High-speed sampling frequency: “320000/ The number of channels” or less. *About high-speed and low-speed setting channels, the number of channels per channel is 2. |
Digital Filter |
Butterworth filter (IIR) Type of filter: LPF, HPF Order of a filter: 1 to 8 Amplitude ratio at cutoff point: -3 dB Attenuation: -6 x N dB/oct. (N is order of the filter) *Simultaneously use with built-in LPF possible. *Application on CAN data not possible. |
---|---|
Data Recording Unit |
CF card Capacity: 128 MB to 16 GB (our recommended only) Maximum data file size (available data file size to be recorded) When the number of repeat times is 1: 4 GB/data file When the number of repeat times is 2: 1 GB/data file (1GB = 1000000000 bytes) |
Control Switch |
UP/DOWN : Changes the display on the small indicator. REC/PAUSE : Starts and pauses data recording. STOP : Stops data recording. BAL. : Execute the balance. LOAD : Loads and sets conditions. OPT. : Conducts the pre-set arbitrary function. ID : Sets the EDX-200A identification No. POWER : POWER switch USB/LAN : Selects a communication interface (USB /LAN) [NOTE] The EDX-200A-1 does not have the UP/DOWN switch and ID switch. |
Indicator |
Channel status display LED:32 Unit status display LED:7 Unit status display organic EL monitor:1 |
Operating Switch |
UP, DOWN: Status display organic EL monitor display switching REC/PAUSE: Start/pause data recording. STOP: Stop data recording. BAL.: Implement balance (Balance adjustment) LOAD: Read and configure conditions from CF card OPT.: Execute arbitrary configured functions ID: EDX identifier configuration POWER: Power switch USB/LAN: Communications I/F, switchable |
External Control Connector |
CONT IN, CONT OUT (Remote control, for synchronous operation) |
Communication interfaces |
USB(USB2.0 High Speed) 1 port Connector: Series B receptacle connector LAN(10/100BASE-T) 2 ports LAN IN connector: For PC communication LAN OUT connector For synchronous operation Connector: RJ45 modular jack connector |
Synchronous Operation |
Max. 8 EDX-200A units can be connected for synchronous operation by using synchronous cables N-95 N-128. Max. 8 EDX-200A units can be connected for synchronous operation by using LAN cables. [NOTE] The synchronous operation is not available with the EDX-200A-1. |
How To Setting Conditions |
Online setting: Set measuring conditions on the PC via the LAN or USB interface. Offline setting: Set measuring conditions by allowing the EDX-200A to read measuring conditions in the CF card. (Use DCS-100A to set measuring conditions.) |
Saving Conditions |
Recording of conditioner configuration conditions and measurement conditions within the EDX built- in nonvolatile memory. Immediate start of data collection using the previously configured measurement conditions after power-on is possible. |
Measuring Modes
Manual measurement Trigger measurement Interval measurement |
|
Manual Measurement |
Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
Trigger Measurement |
Data recording is automatically started when the preset trigger condition is satisfied. *No CAN data of CAN-41A is used as the trigger condition. |
Interval Measurement |
Automatically recording functions based upon previously-set interval conditions Combination with measured mode when in dual sampling (High-speed sampling channel - Low-speed sampling channel) Manual--------------------------------Manual Trigger--------------------------------Manual, interval Interval ------------------------------ Interval |
Starting and Stopping Data Recording | Data recording starts/stops by using the PC,panel switches or the RCU-42A |
---|---|
Balance Operation | Adjust the balance of the strain input channel and conduct the zero suppress of the voltage input CH of the CVM-41A by using the PC, control switches (on the front panel) or the RCU-42A |
Recording Data Format |
Kyowa standard file format KS2 Analysis using optional Data Analysis Software DAS-200A is possible. |
Data Collection | Online using PC, or offline direct reading from CF card to PC |
TEDS Function |
TEDS function is available only when online control from the PC. TEDS compatible conditioner cards: CDV-40B (-F),DPM-42B (-F), DPM-42B-I (-F), CCA-40A (-F),CDV-44AS, CDA-44AS, CDA-45AS, CVM-41A |
Power Supply |
10 to 36 VDC Connector type: RM12BRD-4PH (Hirose) Use DC power supply or AC adapter (Optional accessory) |
Current Consumption | Approx. 2.6 A (12 VDC with 4 CDV-40B card installed) |
Operating Temperature | -20 to 65ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | −30 to 70ºC |
Vibration Resistant |
49.0 m/s2 (5 G), 5 to 55 Hz 1 cycle 1 min., each axis 15 cycles (Non-operating) 29.4 m/s2 (3 G), 5 to 55 Hz 1 cycle 1 min., each axis 15cycles (Operating) |
Impact Resistant | 196.1 m/s2 (20 G) /11 ms |
Dimensions | 185.2 W x 142.8 H x 255 D mm (Excluding protrusions) |
Weight | Approx. 3.7 kg (Approx.4.2 kg with 4 CDV-40B cards installed.) |
Standard Accessories |
DC power cable P-76 USB cable N-38 Ground wire P-72 CF card (1 GB) inserted in the slot Fuses (8 A for 4-slot model) EDX accessory bag Dynamic data acquisition software DCS-100A (DVD) *DCS-100A is optional for models with suffix "-0". Instruction manual (In English & Japanese, in the above DVD) |
---|---|
Optional Accessories |
AC adapter UEA360-1540 (For U.S.A.: SPU61A-106 15 V) Fixing adapter EDX dummy panel EDX1P-DUMMY Remote control unit RCU-42A Monitor unit EMON-20A Synchronous cable N-128 |
SANTA TECHNOLOGY CO.,LTD. (Head Office)
35/218 Moo. 2, Leabkhlongsam Rd., Khlongsam, Khlongluang, Pathumthani 12120
Call 02-101-3454 ,089-006-2766
Fax 02-101-3453
Mail. santatech@gmail.com
Line : @santatech
Web : https://santatechnology.com/