Sensor Interface PCD-430A
Add to Wishlist
Input signals of strain or voltage can be selected channel by channel. 4 unit synchronous sampling using the Stacking Connector Set ST-1A (Optional accessory) TEDS compatible (UI-10A and UI-11A) Sampling frequency: Max. 10 kHz
Availability:
Out of stock
Contact for a quote.
Request for Quotationช่องทางการสั่งซื้ออื่น ๆ
ติดต่อทาง Line
@santatech
ติดต่อทางอีเมล์
santatech@gmail.com
ติดต่อทางโทรศัพท์
02-1013454
Description
The PCD-430A is a carrier-wave measuring instrument for measuring strain gages, strain-gage transducers, and voltage via an USB interface.
Up to 4 units are stacked for measurement in 16 channels.
Specifications
| Measuring Targets | Strain gages and strain-gage transducers |
|---|---|
| Channels | 4 |
| Input Form | Balanced differential input |
| Synchronous Operation | Up to 4 units by 16 channels |
| Compatible Gage Resistance |
Quarter bridge 2-wire system, 3-wire system: 120 Ω Half bridge system, full bridge system: 120 to 1000 Ω |
| Input Connector | D-sub 37-pin connector |
| Bridge Excitation | AC 2 Vrms |
| Gage Factor | 2.00 fixed |
| Balance Adjustment |
Resistance: Within ±2% (±10 k ×10-6 strain) Capacitance: Within 5000 pF |
| Balance Adjustment Methods |
Resistance: Auto balance Capacitance: CST method (Capacitance self-tracking) |
| Nonlinearity | Within ±0.1% FS |
| Range |
200, 500, 1 k, 2 k, 5 k, 10 k, and 20 k ×10-6 strain, -7 steps Accuracy: Within ±0.5% FS |
| Frequency Response | DC to 200 Hz, deviation: Within ±10% |
| Sampling Frequencies |
Max. 10 kHz (Synchronous 4-unit sampling for 16 channels at 10 kHz) |
| LPF |
Transfer characteristic : 2nd order Butterworth Cutoff frequencies : 10, 30, 100 Hz, and FLAT (4 steps) Amplitude ratio at cutoff point : -3 ±1 dB Attenuation : (-12 ±1) dB/oct. |
| AD Converter | 24 bits |
| Setting Value Storage | The range and balance adjustment value etc. are written to nonvolatile memory. |
| TEDS |
Reads information from TEDS-installed sensors. (Input adapters: UI-10A and UI-11A only) Channel name writing (If the manufacturer’s ID is Kyowa) |
| Interfaces |
USB2.0 (Conforms to High-speed USB standards. USB3.0 supported) |
| Stability |
Temperature Zero point: Within ±0.2 ×10-6 strain per ºC Sensitivity: Within ±0.05%/ºC Time Zero point: Within ±0.5 ×10-6 strain per 8h Sensitivity: Within ±0.15%/8h |
| Withstand Voltage | 250 VAC for 1 minute between input and case |
| Operating Temperature | 0 to 40ºC |
| Operating Humidity | 20 to 85% (Non-condensing) |
| Vibration Resistance |
±29.42 m/s2 (3 G) 5 to 200 Hz (12 cycles for each axis, 10 minutes/cycle) |
| Power Supply |
11 to 16 VDC Connector type: RM12BRD-4PH (Hirose) |
| Current Consumption | 0.9 A or less (12 VDC) |
| Dimensions | 210 W x 35 H x 157.5 D mm (Excluding protrusions) |
| Weight | Approx. 750 g |
| Compliance |
Directive 2014/30/EU (EMC) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
Voltage Measurement Mode
| Measuring Targets | Voltage |
|---|---|
| Input Form | Unbalanced |
| Range |
1, 2, 5, 10, 20, and 50 V - 6steps Accuracy: Within ±0.2% FS |
| Frequency Response | DC to 1 kHz, deviation: -3 to 1 dB |
| HPF | 2 steps of 0.2 Hz, OFF |
| LPF |
Transfer characteristic: 2nd order Butterworth Cutoff frequencies: 10, 30, 100, 300 Hz and FLAT (5 steps) Amplitude ratio at cutoff point: -3 ±1 dB Attenuation: (-12 ±1) dB/oct. |
| Stability |
Temperature Zero point: ±0.008%FS/ºC Sensitivity: ±0.02%/ºC Time Zero point: ±0.03%FS/8h Sensitivity: ±0.1%/8h |
| Standard Accessories |
USB cable N-38 Ground wire P-72 Dynamic data acquisition software DCS-100A (DVD) |
|---|---|
| Optional Accessories |
DC power cable P-76 USB cable N-39 Connection cable N-97 Stacking connector set ST-1A Stack fixture CN-20 AC adapter UIA345-12 (For 1 to 4 units of PCD) (For U.S.A.: UNI345-1238) Conversion adapter FV-1A Input adapter for strain-gage transducers UI-10A (TEDS compatible) Input adapter for strain gages UI-11A (TEDS compatible) Input adapter for strain gage with operating lever UI-15A One-touch type input adapter for strain gages UI-16B One-touch type input adapter UI-55A Voltage input adapter UI-30A Data analysis software DAS-200A |
SANTA TECHNOLOGY CO.,LTD. (Head Office)
35/218 Moo. 2, Leabkhlongsam Rd., Khlongsam, Khlongluang, Pathumthani 12120
Call 02-101-3454 ,089-006-2766
Fax 02-101-3453
Mail. santatech@gmail.com
Line : @santatech
Web : https://santatechnology.com/