The ECAN-40A, ETIM-40A, and EGPC-40A are optional cards for EDX-200A. The cards can measure CAN data or GPS information without reducing the number of analog channels and sampling frequencies.
ECAN-40A
Multichannel CAN Card
Specifications
Applicable Models
|
EDX-200A-4H
EDX-200A-2H
(Installed in option slot)
*For EDX-200A-4T, please use ECAN-40A M72.
|
CAN Ports
|
2 (High-speed CAN/low-speed CAN selectable)
|
Channels
|
Up to 512
(Total for 2 ports)
|
Compatible CAN Input Channels
|
CAN 2.0 A/B(Conforming to ISO-11898, ISO-11519-2)
|
Baud Rates
|
High speed CAN
1000, 800, 500, 250, 125, 100, 83.3, 62.5, 50, 33.3, 25, 20, and 10 [kbps]
Low speed CAN
125, 100, 83.3, 62.5, 50, 33.3, 25, 20, and 10 [kbps]
|
CAN Data Output
|
Output at start:
Output any given CAN data when AD conversion starts
Output at stop:
Output any given CAN data when AD conversion stops
Manual output:
Output any given CAN data at an arbitrary timing.
Interval output:
Output any given CAN data in a predetermined fixed cycle.
|
Digital I/O
I/O Points
|
Max. 8
|
I/O Settings
|
Switch among digital input, digital output and remote-controlled input for each bit
(Common applied to all).
*Remote control input: Start and stop measuring, execute BAL, etc.
|
Input Type
|
Isolated type, TTL level input
|
Input Voltage
|
Max. 5 VDC
|
Isolation Methods
|
Digital isolator
|
Output Type
|
Isolated type, open collector type output
(With 10 kΩ internal pull-up resistors)
|
Output Voltage
|
5 VDC
|
Output Current
|
25 mA max. (Per point)
|
Isolation Methods
|
Digital isolator
|
Connector Type
|
CAN port: D-sub connector (Male) 9-pin
Digital I/O port: MDR connector (Female) 14-pin
|
Operating Temperature
|
0 to 50°C, ECAN-40A M72 is -20 to 65°C
|
Operating Humidity
|
20 to 90% (Non-condensing)
|
Storage Temperature
|
-20 to 60°C, ECAN-40A M72 is -30 to 70°C
|
Dimensions
|
22.0 W x 128.0 H x 221.5 D mm
|
Weight
|
Approx. 170 g
|
Compliance
|
Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU)2015/863
(10 restricted substances) (RoHS)
|
|
Note: When using EDX-200A and DCS-101A for arithmetic operation, no CAN measurement is possible.
|
Standard Accessories
|
Connector plug for digital I/O ports
Shell case
CANdb File Read Optional Software DCS-105A
|
ETIM-40A
Time Synchronization Card
Specifications
Applicable Models
|
EDX-200A-4H
EDX-200A-2H
(Installed in option slot)
*For EDX-200A-4T, please use ETIM-40A M72.
|
Synchronization
|
Synchronizes the recording start time of remote EDX-200A units by using the time data received from GPS satellites.
|
GPS Data
|
Latitude, longitude, elevation, course over ground,speed, time, receiving conditions, the number of satellites in use, etc.
Saving format: NMEA format
|
Digital I/O
I/O Points
|
Max. 8
|
I/O Settings
|
Switch among digital input, digital output and remote-controlled input for each bit
(Common applied to all).
*Remote control input: Start and stop measuring, execute BAL, etc.
|
Input Type
|
Isolated type, TTL level input
|
Input Voltage
|
Max. 5 VDC
|
Output Type
|
Isolated type, open collector type output
(With 10 kΩ internal pull-up resistors)
|
Output Voltage
|
5 VDC
|
Output Current
|
25 mA max. (Per point)
|
Isolation Methods
|
Digital isolator
|
Connector Type
|
GPS sensor port: D-sub connector (Male) 9-pin
Digital I/O port: MDR connector (Female) 14-pin
|
Operating Temperature
|
0 to 50°C
ETIM-40A M72 is −20 to 65°C
|
Operating Humidity
|
20 to 90% (Non-condensing)
|
Storage Temperature
|
−20 to 60ºC
ETIM-40A M72 is −30 to 70ºC
|
Dimensions
|
22.0 W x 128.0 H x 221.5 D mm
|
Weight
|
Approx. 160 g
|
Compliance
|
Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU)2015/863
(10 restricted substances) (RoHS)
|
Standard Accessories
|
Connector plug for digital I/O ports
GPS sensor (Cable length: 5 m)
Shell case
|
EGPC-40A
GPS/Multichannel CAN Card
Specifications
Applicable Models
|
EDX-200A-4H
EDX-200A-2H
(Installed in optional slot)
*For EDX-200A-4T, please use EGPC-40A M72.
|
I/O Ports
|
GPS/CAN Shared Port 1 Dsub connector 9 pins (male)
CAN only port 1 Dsub connector 9 pins (male)
Digital I/O port 1 MDR connector 14 pins (female)
|
Channels
|
Up to 512
|
Compatible CAN Versions
|
CAN 2.0A/B
(Conforming to ISO-11898, ISO-11519-2)
|
Baud Rates
|
High speed CAN:
1000, 800, 500, 250, 125, 100, 83.3, 62.5, 50, 33.3, 25, 20, and 10 [kbps]
Low speed CAN:
125, 100, 83.3, 62.5, 50, 33.3, 25, 20, and 10 [kbps]
|
CAN Data Output
|
Output at start:
Output any given CAN data when AD conversion starts
Output at stop:
Output any given CAN data when AD conversion stops
Manual output:
Output any given CAN data at an arbitrary timing.
Interval output:
Output any given CAN data in a predetermined fixed cycle.
|
GPS Data
|
Latitude, longitude, elevation, course over ground,speed, time, receiving conditions, the number of satellites in use, etc.
Saving format: NMEA format
|
Synchronization
|
Synchronizes the recording start time of remote EDX-200A units by using the time data received from GPS satellites.
|
Digital I/O
I/O Points
|
Max. 8
|
I/O Settings
|
Switch among digital input, digital output and remote-controlled input for each bit
(Common applied to all).
*Remote-controlled input: Start and stop measuring, execute BAL, etc.
|
Input Type
|
Isolated type (Digital isolator), TTL level input
|
Input Voltage
|
Max. 5 VDC
|
Output Type
|
Isolated type (Digital isolator)
Open collector type output
(With 10 kΩ internal pull-up resistors)
|
Output Voltage
|
5 VDC
|
Output Current
|
25 mA max. (Per point)
|
Operating Temperature
|
0 to 50ºC
EGPC-40A M72 is -20 to 65ºC
|
Operating Humidity
|
20 to 90% (Non-condensing)
|
Storage Temperature
|
-20 to 60ºC
EGPC-40A M72 is -30 to 70ºC
|
Dimensions
|
22.0 W x 128.0 H x 221.5 D mm
|
Weight
|
Approx. 170 g
|
Compliance
|
Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU)2015/863
(10 restricted substances) (RoHS)
|
|
When using EDX-200A and DCS-101A for arithmetic operation, no CAN measurement is possible.
|
Standard Accessories
|
Connector plug for digital I/O ports
GPS sensor (Cable length: 5 m)
Shell case
CANdb File Read Optional Software DCS-105A
|
SANTA TECHNOLOGY CO.,LTD. (Head Office)
35/218 Moo. 2, Leabkhlongsam Rd., Khlongsam, Khlongluang, Pathumthani 12120
Call 02-101-3454 ,089-006-2766
Fax 02-101-3453
Mail. santatech@gmail.com
Line : @santatech
Web : https://santatechnology.com/