Universal Recorder EDX-200A-1
Add to Wishlist
Incorporated real-time digital filter.8th digital filter enables acquisition of clear waveform.High-speed/low-speed dual samplingMeasurement of high-speed and low-speed phenomena while reducing data quantities is possible.
Availability:
1 in stock
Contact for a quote.
Request for Quotation Download Datasheetช่องทางการสั่งซื้ออื่น ๆ
ติดต่อทาง Line @santatech ติดต่อทางอีเมล์ santatech@gmail.com ติดต่อทางโทรศัพท์ 02-1013454Description
Models |
EDX-200A-1 (With DCS-100A) EDX-200A-1-1 (With DCS-100A and DCS-101A) |
---|---|
Measuring Targets |
Strain (Gage, transducer) Voltage Thermocouples Pulse (F/V) Piezoelectric acceleration (Built-in amplifier) CAN signals GPS |
Conditioner Cards for Analog Inputs |
The conditioner cards for EDX series [Note] The EDX-200A-4T can use only the CVM-41A,CDV-40B, CDV-40B-F and CAN-41A which performed temperature extension processing. [Note] The EDX-200A limits the number of CFV-40A. The number of CFV-40A is up to 1. |
Conditioner Cards for CAN Data Inputs |
CAN card (2 ports, max. 256 channels): CAN-41A [Note] Can install one CAN-41A to the final slot. |
Voice Memo Input |
1 channel (Input voice memo data is recorded together with the measurement data.) Use remote control unit RCU-42A. (Optional accessory) Use the Data Analysis Software DAS-200A (optional accessory) to play back recorded voice memos. |
Sampling
Sampling Method | Simultaneously all channels |
---|---|
Sampling Mode |
Normal: Records all channels' data at the same sampling clock. Dual: Enables high-speed sampling or low-speed sampling to every CH for recording. |
Sampling Frequencies
Normal-sampling Mode |
1-2-5 series 1 Hz to 100 kHz 1 Hz to 2 kHz When using CAN-41A 2n series 2 to 65536 Hz 2 to 2048 Hz When using CAN-41A |
---|---|
Dual-sampling Mode |
High-speed sampling [Sf] 1-2-5 series 1 Hz to 100 kHz 1 Hz to 2 kHz when using CAN-41A 2n series 2 to 65536 Hz 2 to 2048 Hz when using CAN-41A Low-speed sampling [Ss] 1-2-5 series The division frequencies from high-speed sampling, and Ss ≤ Sf/4 2n series The division frequencies from high-speed sampling, and Ss ≤ Sf/4 |
Channels
Normal-sampling Mode | Max. 32 channels, 320 k/I (I is the integer part of the set sampling frequency.) |
---|---|
Dual-sampling Mode | Max. 64 channels, 320 k/I (I is the integer part of the set sampling frequency.). “High-speed and low-speed” setting counts as 2 channels. |
When Using CAN-41A | Channels of CAN data |
The Number of Sampling Frequency
Normal Mode | “320000/ The number of channels” or less |
---|---|
Dual Mode |
High-speed sampling frequency: “320000/ The number of channels” or less. *About high-speed and low-speed setting channels, the number of channels per channel is 2. |
Digital Filter |
Butterworth filter (IIR) Type of filter: LPF, HPF Order of a filter: 1 to 8 Amplitude ratio at cutoff point: -3 dB Attenuation: -6 x N dB/oct. (N is order of the filter) *Simultaneously use with built-in LPF possible. *Application on CAN data not possible. |
---|---|
Data Recording Unit |
CF card Capacity: 128 MB to 16 GB (our recommended only) Maximum data file size (available data file size to be recorded) When the number of repeat times is 1: 4 GB/data file When the number of repeat times is 2: 1 GB/data file (1GB = 1000000000 bytes) |
Control Switch |
UP/DOWN : Changes the display on the small indicator. REC/PAUSE : Starts and pauses data recording. STOP : Stops data recording. BAL. : Execute the balance. LOAD : Loads and sets conditions. OPT. : Conducts the pre-set arbitrary function. ID : Sets the EDX-200A identification No. POWER : POWER switch USB/LAN : Selects a communication interface (USB /LAN) [NOTE] The EDX-200A-1 does not have the UP/DOWN switch and ID switch. |
Indicator |
Channel status display LED: 8 Unit status display LED: 4 |
Operating Switch |
REC/PAUSE: Start/pause data recording. STOP: Stop data recording. BAL.: Implement balance (Balance adjustment) LOAD: Read and configure conditions from CF card OPT.: Execute arbitrary configured functions POWER: Power switch USB/LAN: Communications I/F, switchable |
External Control Connector |
CONT. IN (Remote control, for synchronous operation) |
Communication interfaces |
USB(USB2.0 High Speed) 1 port Connector: Series B receptacle connector LAN(10/100BASE-T) 2 ports LAN IN connector: For PC communication LAN OUT connector For synchronous operation Connector: RJ45 modular jack connector [NOTE] The EDX-200A-1 does not have the LAN OUT connector for the synchronous operation. |
How To Setting Conditions |
Online setting: Set measuring conditions on the PC via the LAN or USB interface. Offline setting: Set measuring conditions by allowing the EDX-200A to read measuring conditions in the CF card. (Use DCS-100A to set measuring conditions.) |
Saving Conditions |
Store the conditioner cards' setting conditions and measuring conditions in nonvolatile memory in the EDX-200A. When turning ON the EDX-200A, the user can immediately start data recording with previously set conditions. |
Measuring Modes
Manual measurement Trigger measurement Interval measurement |
|
Manual Measurement |
Data recording is manually started or stopped when data is recorded to a preset number of measured data. Manual mode allows recording of voice memo during data recording. |
Trigger Measurement |
Data recording is automatically started when the preset trigger condition is satisfied. *No CAN data of CAN-41A is used as the trigger condition. |
Interval Measurement |
Automatically recording functions based upon previously-set interval conditions Combination with measured mode when in dual sampling (High-speed sampling channel - Low-speed sampling channel) Manual--------------------------------Manual Trigger--------------------------------Manual, interval Interval ------------------------------ Interval |
Starting and Stopping Data Recording | Data recording starts/stops by using the PC,panel switches or the RCU-42A |
---|---|
Balance Operation | Adjust the balance of the strain input channel and conduct the zero suppress of the voltage input CH of the CVM-41A by using the PC, control switches (on the front panel) or the RCU-42A |
Recording Data Format |
Kyowa standard file format KS2 Analysis using optional Data Analysis Software DAS-200A is possible. |
Data Collection | Online using PC, or offline direct reading from CF card to PC |
TEDS Function |
TEDS function is available only when online control from the PC. TEDS compatible conditioner cards: CDV-40B (-F),DPM-42B (-F), DPM-42B-I (-F), CCA-40A (-F),CDV-44AS, CDA-44AS, CDA-45AS, CVM-41A |
Power Supply |
10 to 33 VDC Connector type: RM12BRD-4PH (Hirose) Use DC power supply or AC adapter (Optional accessory) |
Current Consumption |
Approx. 1.0 A (12 VDC with 1 CDV-40B card installed) |
Operating Temperature | 0 to 50ºC |
Operating Humidity | 20 to 90% (Non-condensing) |
Storage Temperature | −20 to 60ºC |
Vibration Resistant |
49.0 m/s2 (5 G), 5 to 55 Hz 1 cycle 1 min., each axis 15 cycles (Non-operating) 29.4 m/s2 (3 G), 5 to 55 Hz 1 cycle 1 min., each axis 15cycles (Operating) |
Impact Resistant | 294.2 m/s2 (30 G) /11 ms |
Dimensions | 148 W x 53 H x 257 D mm (Excluding protrusions) |
Weight | Approx. 0.9 kg (Approx.1.1 kg with 1 CDV-40B cards installed.) |
Compliance |
Directive 2014/30/EU (EMC) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
Standard Accessories |
DC power cable P-76 USB cable N-38 Ground wire P-72 CF card (1 GB) inserted in the slot EDX accessory bag Dynamic data acquisition software DCS-100A (DVD) *DCS-100A is optional for models with suffix "-0". Instruction manual (In English & Japanese, in the above DVD) |
---|---|
Optional Accessories |
AC adapter UIA345-12 (For U.S.A.: UNI345-1238) Fixing adapter EDX dummy panel EDX1P-DUMMY Remote control unit RCU-42A Monitor unit EMON-20A |
SANTA TECHNOLOGY CO.,LTD. (Head Office)
35/218 Moo. 2, Leabkhlongsam Rd., Khlongsam, Khlongluang, Pathumthani 12120
Call 02-101-3454 ,089-006-2766
Fax 02-101-3453
Mail. santatech@gmail.com
Line : @santatech
Web : https://santatechnology.com/