เครื่องวัดสายไฟเบอร์ออฟติก Fluke Fiber QuickMap

SKU: fiber quickMa
Multimode Fiber Distance and Fault Locator Works on multimode fiber 50/125µm and 62.5/125 µm 850 nm output wavelength. Measure up to 4 921 feet (1 500 metres) of fiber in seconds Locate severe bends high-loss splices breaks and dirty connector
Availability:

1 in stock

ติดต่อขอใบเสนอราคา

ขอใบเสนอราคา

รายละเอียด

เครื่องตรวจซ่อมเครือข่ายไฟเบอร์ออปติกแบบมัลติโหมด ขนาดพกพา Fiber QuickMap

Multimode Fiber Distance and Fault Locator


  • Works on multimode fiber, 50/125µm and 62.5/125 µm
  • 850 nm output wavelength. Measure up to 4,921 feet (1,500 metres) of fiber in seconds
  • Locate severe bends, high-loss splices, breaks and dirty connectors in multimode fiber
  • Measure and locate high-loss splices
  • Locate the end of a fiber
  • Find potential sources of high bit error rates caused by reflectance from dirty or poor connections
  • Detects live optical signals before it begins testing
  • Quick set-up. Connect your fiber and press the Test button. No lengthy set-up necessary
  • Find problems quickly. Six-second test time—no more blind troubleshooting that can waste hours
  • Change the Index of Refraction (IOR) to improve fiber length accuracy
  • Visible in dark areas. Backlighted display turns off automatically
  • Removable SC adapter is easily cleaned
  • Optional LC, ST and FT interchangeable adapters are available
  • Long battery life, 1,500 tests (typical) from 2 AA alkaline batteries
  • Rugged construction; vibration and drop tested to 1 meter

Specifications

  • Models
    Operating temperature with the battery 0ºC to 50ºC
    Non-operating temperature -20ºC to 60ºC
    Operating relative humidity (without condensation) 95% (10ºC to 35ºC) 75% (35ºC to 40ºC) uncontrolled < 10ºC
    Vibration Random, 5 Hz to 500 Hz, MIL-PRF-28800F CLASS 2
    Shock 1 meter drop test
    Altitude 3000m
    EMC EN 61326-1: 2004
    Battery type 2 AA alkaline batteries (no battery charger)
    Battery life 1500 tests (typical)
    Laser safety Class 1 CDRH Complies to EN 60825-2
    LCD type Backlit black and white (segments)
    Index of refraction range 1.45 to 1.5 (factory default is 1.496)
    Auto turn off Automatically turns off after 5 minutes if no keys are pressed. Backlight turns off first.
    Factory calibration interval None
    Output wavelengths 850 nm ± 10 nm
    Laser classification Class 1 CDRH Complies to EN 60825-2
    Dynamic range >11 dB
    Maximum distance 1500 meters or 4921 feet
    Maximum number of incidents shown 9
    Distance accuracy (0 m to 1500 m or 0 ft to 4921 ft) ± (1 m + 0.1 % x length) for reflective incidents1 ± (3 m + 0.1 % x length) for non-reflective incidents2
    Testing speed < 6 seconds typical
    Connector Removable/cleanable SC adapter, UPC polish
    Fiber types tested 50/125 µm or 62.5/125 µm multimode
    Detection of reflective incidents3 -35 dB default threshold (User selectable: -20 dB to -45 dB in 5 dB increments)
    Reflectance accuracy4 ± 4 dB
    Maximum reflectance measurement -20 dB
    Detection of loss incidents5 0.70 dB default threshold (user-configurable from 0.5 dB to 6.1 dB in 0.2 dB increments)
    Bulkhead quality If no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft.
    Live fiber detection Detects optical signals from 600 nm to 1050 nm and shows ACTIVE LINE if a signal is there. Looks for a signal every 3 seconds after the first detec-tion. +7 dB maximum input power.
    Certifications and compliance European Union    Conforms to relevant European Union
                    directives
    Australian Gray    Conforms to relevant Australian standards
    Canadian Standards   Listed by the Canadian Standards Association CSA
                   C22.2 No. 61010.1.04
    FCC Rules   Conforms to FCC Rules, Part A, Class A
    1. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for reflective incidents: ±1 m from 1 m to 1.5 km.
    2. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for non-reflective incidents: ±2 m for lengths £15 m, otherwise ±1 m.
    3. Finds and gives the location of an incident that has a reflectance larger than -55 dB. Detects incidents >1m after the bulkhead connector when the bulkhead reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB.
    4. With a backscatter coefficient of -63 dB at 850 nm using a calibrated -14 dB reference.
ติดต่อสอบถาม คลิก
อีเมล์
โทรศัพท์
แชทผ่าน LINE
แชทผ่าน Facebook
ดูแผนที่

please wait.....