ชุดเครื่องมือวัดเเสง Fluke SimpliFiber Pro Optical Power Meter and Fiber Test Kits
Simple-to-use fiber-loss tester with advanced time-saving features. Choose from various kits with configurations to meet your fiber verification, inspection, and cleaning needs.
Single-port, simultaneous dual-wavelength feature completes testing in half the time and saves measurements from both wavelengths into one record
Additional wavelengths of 1490 and 1625 nm
CheckActive™ feature emits an audible tone and displays an icon when a live fiber is detected, eliminating the need to set up a measurement
FindFiber™ Remote ID enables one individual to quickly identify cable connections or routings (especially useful at patch panels), eliminating the need for multiple technicians on opposite ends of a fiber link to match color combinations
Min/Max capability automates precision tracking of intermittent power fluctuations
Large internal memory save 1000 results which enables continuous testing and recording
LinkWare Cable Test Management software helps to analyze test results and create professional test reports
Various kit configurations for all “first line” fiber handling needs, including fiber verification, inspection, and cleaning – all housed in a professional, rugged carrying case
Mag Kit Strap Attachment - Strong rare earth magnet attaches to metal surfaces in the testing environment, allowing the technician to work "hands free"
Specifications
Environmental Specifications
Operating Temperature
-10º C to 50º C
Storage Temperature
-20º C to 50º C
Operating Humidity
- 95% (10º C to 35º C) Non-Condensing
- 75% (35º C to 40º C) Non-Condensing
- Uncontrolled <10º C
EMI, RFI, EMC
Standards compliant1
1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
Optical Power Meter
Detector Type
InGaAs
Calibrated Wavelengths
850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm
Measurement Range
- +10 to -52 dBm (850 nm)
- +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)
Power Measurement Linearity
- ±0.2 dB (850 nm)1
- ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2
Power Measurement Uncertainty3
±0.25 dB
Display Resolution, dB or dBm
0.01 dB
Auto Dual-Wavelength Switching
Yes
Power Display Units
dBm, mW, μW
Auto-Wavelength Detection
Yes
Data Storage
1000 records, multiple wavelengths per record
External Interface
USB, 2.0 full speed
Optical Connector
Removable adapter, SC adapter as default, optional adapters include LC, ST
Display update rate
1 reading per second
Reference
Individually set for each wavelength
FindFiber ID detection
Yes
Power Requirement
2 AA Alkaline batteries
Battery Life4
> 50 Hours (typical)
Automatic Power Off
10, 20, 30 or 60 minutes (can be disabled by user)
Low Battery Warning
Yes, low battery icon blinks
Size (L x W x H)
6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)
Weight
11.5 oz (325 grams)
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm
2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm
3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,
4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Multimode Optical Source
Emitter Type
LED
Central Wavelength
850 nm, 1300 nm
Wavelength Accuracy
- 850 nm: +/-30 nm
- 1300 nm: +/- 20 nm
Spectral Width (FWHM)
- 850 nm: 50 nm (typical)
- 1300 nm: 135 nm (typical)
Minimum Output Power
850/1300 nm: ³ -20 dBm
Power Output Stability1
±0.1 dB over 8 hours
Auto Dual-Wavelength Switching
Yes. Can be enabled/disabled by user.
Optical Output Connector
Fixed SC
FindFiber Code Generation
Yes. Fixed at ID 1.
Modes
CW, 2 kHz modulated, Auto-wavelength
Power Requirement
2 AA Alkaline batteries.
Battery Life2
40 hrs (typical)
Automatic Power Off
30 minutes (can be disabled by user)
Low Battery Warning
Yes, LED blinks
Size (L x W x H)
5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight
1.8 oz (278 g)
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Singlemode Optical Source
Emitter Type
1310 nm/1550 nm: dual FP laser
1490 nm/1625 nm: dual DFB laser
Central wavelength
- 1310 nm: ±20 nm
- 1550 nm: ±30 nm
- 1490 nm: ±3 nm
- 1625 nm: ±5 nm
Wavelength Accuracy
- 1310 nm: +/- 20 nm
- 1550 nm: +/- 30 nm
Spectral width (RMS)
- 1310 nm: 2 nm (maximum)
- 1550 nm: 3 nm (maximum)
- 1490 nm/1625 nm: 1 nm (maximum)
Minimum output power
1310/1550 nm ≥ -7dBm (typical)
1490 nm/1625 nm: ≥ -3 dBm (typical)
Power Output Stability1
±0.25 dB over 8 hours
Auto Dual-Wavelength Switching
Yes. Can be enabled or disabled by user.
Optical Connector
Fixed SC
Launch Condition
9/125 μm fiber
FindFiber Code Generation
1310/1550 source is fixed at ID 2
1490 nm/1625 nm is fixed at ID 3.
Modes
CW, 2 kHz modulated, Auto-wavelength
Power Requirement
2 AA Alkaline batteries
Battery Life2
30 hrs (typical)
Automatic Power Off
30 minutes (can be enabled or disabled by user)
Low Battery Warning
LED blinks.
Size (L x W x H)
5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight
9.8 oz (278 grams)
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
FindFiber Source Specifications
Emitter Type
Laser
Source Connector
Fixed SC
FindFiber Code Generation
1 through 8. Default is 3.
Power On/Low-battery Indicator
LED
Power Requirement
2 AA Alkaline batteries
Battery Life
> 80 Hours (typical)
Automatic Power Off
30 minutes
Low Battery Warning
LED blinks
Size (L x W x H)
7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)
Weight
4.4 oz (125 g)
Safety
Meets Class 1 CDRH
Environmental Specifications | |
Operating Temperature | -10º C to 50º C |
Storage Temperature | -20º C to 50º C |
Operating Humidity |
|
EMI, RFI, EMC | Standards compliant1 |
1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
Optical Power Meter | |
Detector Type | InGaAs |
Calibrated Wavelengths | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm |
Measurement Range |
|
Power Measurement Linearity |
|
Power Measurement Uncertainty3 | ±0.25 dB |
Display Resolution, dB or dBm | 0.01 dB |
Auto Dual-Wavelength Switching | Yes |
Power Display Units | dBm, mW, μW |
Auto-Wavelength Detection | Yes |
Data Storage | 1000 records, multiple wavelengths per record |
External Interface | USB, 2.0 full speed |
Optical Connector | Removable adapter, SC adapter as default, optional adapters include LC, ST |
Display update rate | 1 reading per second |
Reference | Individually set for each wavelength |
FindFiber ID detection | Yes |
Power Requirement | 2 AA Alkaline batteries |
Battery Life4 | > 50 Hours (typical) |
Automatic Power Off | 10, 20, 30 or 60 minutes (can be disabled by user) |
Low Battery Warning | Yes, low battery icon blinks |
Size (L x W x H) | 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm) |
Weight | 11.5 oz (325 grams) |
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm
2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm
3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,
4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Multimode Optical Source | |
Emitter Type | LED |
Central Wavelength | 850 nm, 1300 nm |
Wavelength Accuracy |
|
Spectral Width (FWHM) |
|
Minimum Output Power | 850/1300 nm: ³ -20 dBm |
Power Output Stability1 | ±0.1 dB over 8 hours |
Auto Dual-Wavelength Switching | Yes. Can be enabled/disabled by user. |
Optical Output Connector | Fixed SC |
FindFiber Code Generation | Yes. Fixed at ID 1. |
Modes | CW, 2 kHz modulated, Auto-wavelength |
Power Requirement | 2 AA Alkaline batteries. |
Battery Life2 | 40 hrs (typical) |
Automatic Power Off | 30 minutes (can be disabled by user) |
Low Battery Warning | Yes, LED blinks |
Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
Weight | 1.8 oz (278 g) |
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Singlemode Optical Source | |
Emitter Type |
1310 nm/1550 nm: dual FP laser 1490 nm/1625 nm: dual DFB laser |
Central wavelength |
|
Wavelength Accuracy |
|
Spectral width (RMS) |
|
Minimum output power |
1310/1550 nm ≥ -7dBm (typical) 1490 nm/1625 nm: ≥ -3 dBm (typical) |
Power Output Stability1 | ±0.25 dB over 8 hours |
Auto Dual-Wavelength Switching | Yes. Can be enabled or disabled by user. |
Optical Connector | Fixed SC |
Launch Condition | 9/125 μm fiber |
FindFiber Code Generation |
1310/1550 source is fixed at ID 2 1490 nm/1625 nm is fixed at ID 3. |
Modes | CW, 2 kHz modulated, Auto-wavelength |
Power Requirement | 2 AA Alkaline batteries |
Battery Life2 | 30 hrs (typical) |
Automatic Power Off | 30 minutes (can be enabled or disabled by user) |
Low Battery Warning | LED blinks. |
Size (L x W x H) | 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm) |
Weight | 9.8 oz (278 grams) |
1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
FindFiber Source Specifications | |
Emitter Type | Laser |
Source Connector | Fixed SC |
FindFiber Code Generation | 1 through 8. Default is 3. |
Power On/Low-battery Indicator | LED |
Power Requirement | 2 AA Alkaline batteries |
Battery Life | > 80 Hours (typical) |
Automatic Power Off | 30 minutes |
Low Battery Warning | LED blinks |
Size (L x W x H) | 7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm) |