เครื่องวัดสายไฟเบอร์ออฟติก วิเคราะห์การเชื่อมต่อสายไฟเบอร์ Fluke Fiber OneShot PRO

SKU: Fiber OneShot
Fiber OneShot™ PRO Single Mode Fiber Distance and Fault Locator Works on single mode fiber 9/125µm 1550nm output wavelength. Compatible with standard PON wavelengths: 1310 1490 1550 and 1625nm Measure up to 75 459 feet (23 000 metres) of fiber
Availability:

1 in stock

ติดต่อขอใบเสนอราคา

ขอใบเสนอราคา

รายละเอียด

เครื่องวัดสายไฟเบอร์ออฟติก วิเคราะห์การเชื่อมต่อสายไฟเบอร์ Fluke Fiber OneShot PRO

Fiber OneShot™ PRO

Single Mode Fiber Distance and Fault Locator

  • Works on single mode fiber, 9/125µm
  • 1550nm output wavelength. Compatible with standard PON wavelengths: 1310, 1490, 1550 and 1625nm
  • Measure up to 75,459 feet (23,000 metres) of fiber in seconds
  • Locate severe bends, high-loss splices, breaks and dirty connectors in singlemode fiber
  • Measure and locate high loss connections and breaks
  • Locate the end of a fiber
  • Find potential sources of high bit error rates caused by reflectance from dirty or poor connections
  • Detects live optical signals before it begins testing
  • Quick set-up. Connect your fiber and press the Test button. No lengthy set-up necessary
  • Find problems quickly. Six-second test time—no more blind troubleshooting that can waste hours
  • Change the Index of Refraction (IOR) to improve fiber length accuracy
  • Visible in dark areas. Backlighted display turns off automatically
  • Removable SC adapter is easily cleaned
  • Optional LC, ST and FT interchangeable adapters are available
  • Long battery life, 1,500 tests (typical) from 2 AA alkaline batteries
  • Rugged construction; vibration and drop tested to 1 meter
  • Fluke 414D Distance Measuring Laser (เครื่องวัดระยะห่างเลเซอร์)
  • Fluke 424D Distance Measuring Laser (เครื่องวัดระยะห่างเลเซอร์)

  • Specifications

    Specifications are typical.
    Dimensions

    17.5 cm H
    7.8 cm W
    3.8 cm D
    .35 kg weight including batteries

    Operating temperature with the battery 0ºC to 50ºC
    Non-operating temperature -20ºC to 60ºC
    Operating relative humidity
    (without condensation)
    95% (10ºC to 35ºC)
    75% (35ºC to 40ºC)
    uncontrolled < 10ºC
    Vibration Random, 5 Hz to 500 Hz, MIL-PRF- 28800F CLASS 2
    Shock 1-metre drop test
    Altitude 9,842 feet/3000 metres
    EMC EN 61326-1:2004
    Battery type 2 AA alkaline batteries (no battery charger)
    Battery life More than 1500 tests (typical)
    Laser safety Class 1 CDRH
    Complies to EN 60825-2
    LCD type Backlit black and white (segments)
    Index of refraction range 1.45 to 1.5 (factory default is 1.468)
    Auto turnoff Automatically turns off after 5 minutes if no keys are pressed.
    Backlight turns off first.
    Factory calibration interval None
    Output wavelengths 1550nm ± 20nm at 25ºC
    Laser classification Class 1 CDRH Complies to EN 60825-2
    Maximum distance 75,459 feet or more than 23,000 metres
    Maximum number of incidents shown 9
    Distance accuracy ± (1 m + 1% x length) for reflective incidents
    ± (3 m + 1% x length) for non-reflective incidents2
    Testing speed 5 seconds typical testing time
    Connector Removable/cleanable SC adapter, UPC polish
    Fiber types tested 9/125μm singlemode
    Detection of reflective incidents3 -45 dB default threshold (user-selectable: -24 dB to -62 dB in 1 dB increments)
    Maximum reflectance measurement -24 dB
    Detection of loss incidents4 1.5 dB default threshold
    Bulkhead quality If no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft.
    Live fiber detection

    Detects optical signals from 1250nm to 1625nm and shows ACTIVE LINE if a signal is there.

    Looks for a signal every 3 seconds after the first detection. +7 dB maximum input power.

    European Union Conforms to relevant European Union directives
    Australian Gray Conforms to relevant Australian standards
    Canadian Standards Listed by the Canadian Standards Association CSA C22.2 No. 61010.1.04
    FCC Rules Conforms to FCC Rules, Part A, Class A

    1  ± user-configurable Index of Refraction (IOR) error ± the incident location error.

    2  ± user-configurable Index of Refraction (IOR) error ± the incident location error.

    3  Detects the location of an incident that has a reflectance larger than -62 dB. Detects incidents >2 m after the bulkhead connector when the bulkhead reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB.

    4  Detects incidents >10 m after the bulkhead connector or any prior incident when the bulkhead reflectance is <-35 dB and the reflectance of any prior incident is  <-35 dB. The maximum link loss prior to the incident is <7 dB.


     

ติดต่อสอบถาม คลิก
อีเมล์
โทรศัพท์
แชทผ่าน LINE
แชทผ่าน Facebook
ดูแผนที่

please wait.....