Fluke DSX CableAnalyzer Series Copper Cable Certifiers
Add to Wishlist
Accelerates every step of the copper certification process Versiv™ modular design supports copper certification fiber optic loss OTDR testing and fiber end-face inspection Unmatched speed for Cat 6A 8 Class FA I/II and all current standards Proj
Availability:
1 in stock
Contact for a quote.
Request for Quotationช่องทางการสั่งซื้ออื่น ๆ
ติดต่อทาง Line
@santatech
ติดต่อทางอีเมล์
santatech@gmail.com
ติดต่อทางโทรศัพท์
02-1013454
Description
Specifications
| Cable Types | |
| Shielded and unshielded pair LAN cabling |
TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
| Standard Link Interface Adapters | |
| Permanent link adapters |
Plug type: shielded RJ45 Optional Plug type: Tera |
| Channel Adapters |
Jack type: shielded RJ45 Optional Jack type: Tera, GG45 |
| Test Standards | |
| TIA | Category 3, 4, 5, 5e, 6, 6A, 8 per TIA 568-C.2 |
| ISO/IEC | Class C and D, E, EA, F, FA and I/II certification per ISO/IEC |
| Maximum frequency |
DSX-8000: 2000 MHz; DSX-5000: 1000 MHz |
| General Specifications | |
| Speed of Autotest | DSX-8000: Full 2-way Autotest of Category 5e or 6/Class D or E: 7 seconds. Full 2-way Autotest of Category 6A/Class EA: 8 seconds. Full 2-way Autotest of Category 8: 16 seconds |
| DSX-5000: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds | |
| Supported test parameters (The selected test standard determines the test parameters and the frequency range of the tests) | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Pair-to-Pair Resistance Unbalance, Pair Resistance Unbalance, Insertion Loss (Attenuation), Return Loss (RL), Common Mode Return loss (CMRL), Near End Crosstalk (NEXT), Far End Crosstalk (FEXT), Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien NEXT (PS ANEXT), Power Sum Alien Attenuation NEXT Ratio Far End (PS AACR-F), Common Mode to Differential Mode NEXT (CDNEXT),Transverse Conversion Loss (TCL), Equal Level Transverse Conversion Transfer Loss (ELTCTL) |
| Input protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with shock absorbing overmold |
| Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
| Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main unit and remote: | Lithium ion battery pack, 7.2 V |
| Typical battery life: | 8 hours |
| Charge time* | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity. |
| Languages supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
| Calibration | Service center calibration period is 1 year |
| Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
| Environmental Specifications | |
| Operating Temperature | 32°F to 113°F (0°C to 45°C) |
| Storage Temperature | -14°F to +140°F (-10°C to +60°C) |
| Operating relative humidity |
0 % to 90 %, 32°F to 95 °F (0°C to 35°C) 0 % to 70 %, 95°F to 113 °F (35°C to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
| Operating altitude |
13,123 ft (4,000 m) 10,500 ft (3,200 m) with ac adapter |
| EMC | EN 61326-1 |
| Performance Specifications ** | ||
| DSX-8000 | Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G |
| Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI | |
| DSX-5000 | Category 6A/Class EA test modes (or lower link categories) | Exceed Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1. |
| Class FA test modes | Exceed Level V requirements as in the draft 4th edition of IEC 61935-1. | |
| Length of Twisted Pair Cabling1 | ||
| Without Remote | With Remote | |
| Range | 800 m (2600 ft) | 150 m (490 ft) |
| Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |
| Accuracy |
± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
± (0.3 m + 2 %) |
| Propagation Delay | ||
| Without Remote | With Remote | |
| Range | 4000 ns | 750 ns |
| Resolution | 1 ns | 1 ns |
| Accuracy |
± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
± (2 ns + 2 %) |
| Delay Skew | |
| Range | 0 ns to 100 ns |
| Resolution | 1 ns |
| Accuracy | ± 10 ns |
| DC Loop Resistance Test | |
| Range | 0 Ω to 540 Ω |
| Resolution | 0.1 Ω |
| Accuracy | ± (1 Ω + 1 %) |
| Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |