Charge Amplifier Card CCA-40A
Add to Wishlist1 in stock
Contact for a quote.
Request for Quotationช่องทางการสั่งซื้ออื่น ๆ
ติดต่อทาง Line
@santatech
ติดต่อทางอีเมล์
santatech@gmail.com
ติดต่อทางโทรศัพท์
02-1013454
Description
The cards are for measuring strain, voltage, acceleration, and temperature. CAN data is supported. Isolated amplifier cards and carrier-wave amplifier cards also available for countermeasure against noise.
Specifications
Measuring Targets
Piezoelectric accelerometers
Applied Accelerometers
Built-in amplifier (Voltage output) type
Channels
8
Power Supply to Sensors
Constant current power
(Current: 4 mA, excitation voltage: approx. 24 VDC, load 1 kΩ or less)
Frequency Response
1 to 20 kHz (Deviation: +1 dB, -3 dB)
Measuring Range
20, 50, 100, 200, 500, 1000, 2000, 5000 mV and OFF - 9 steps
Accuracy: Within ±1%FS
Calibration
[DC CAL]
±100% and ±50% of each range
Accuracy: Within ±0.2%FS
[AC CAL]
100% and 50% of each range
Accuracy: Within ±1%FS
Frequency accuracy: Within 100 Hz ±5%
LPF
Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 300, 1 k, 3 k, 10 k Hz, and FLAT (5 steps)
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-12 ±1) dB/oct.
Distortion Factor
1% or less
Resolution
16 bits
Monitor Output
Accuracy: Within ±5 V ±1% (At + FS)
TEDS
Reads information from TEDS-installed sensors.
Compliance
Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS)
Standard Accessories
Input cable U-111
Optional Accessories
Integrated output cable U-62
Conversion adapter (BNC-miniature) BNCP-C25J-A
Conversion adapter (Miniature-Tajimi) CCA-1B
Conversion adapter (BNC-Tajimi) CCA-2B