Conditioner cards for EDX-100A EDX-200A and EDX-5000A. EDX-5000A does not support CAN card CAN-41A.
Our team will contact you with a quotation within 24 hours.
The cards are for measuring strain, voltage, acceleration, and temperature. CAN data is supported. Isolated amplifier cards and carrier-wave amplifier cards also available for countermeasure against noise.
Specifications
Measuring Targets
Strain gages (Full bridge system)
Strain-gage transducers
Voltage
Channels
4
Input Resistance
Approx. 10 MΩ + 10 MΩ (Strain mode)
Approx. 1 MΩ (Voltage mode)
Input Format
Balanced differential input (Strain mode)
Unbalanced input (Voltage mode)
IMRR
120 dB (When 500 ×10-6 strain range)
Gage Factor
2.00 fixed (Strain mode)
Frequency Response
[With DC coupling]
DC to 5 kHz, deviation within +1 dB, -3 dB
[DC cut (With AC coupling)]
0.2 Hz (See the HPF)
Bridge Excitation
Within 2 VDC ±2% (Strain mode)
Range Accuracy
Within ±0.3% FS
Compatible Bridge Resistance
120 to 1000 Ω (Strain mode)
Measuring Range
500, 1 k, 2 k, 5 k, 10 k, 20 k ×10-6 strain, and OFF
(Strain mode)
1, 2, 5, 10, 20, 50 V, and OFF
(Voltage mode)
Balance Adjustment Range
Within ±2.4% (±12000 ×10-6 strain)
(At strain measurement)
Within ±5 V
(At voltage measurement)
ZERO Accuracy
Within ±0.3% FS (Voltage OFF mode)
Nonlinearity
Within ±0.1% FS
Calibration Values (CAL)
Output at ±100% and ±50% of each range
Accuracy: Within ±0.3%FS
Monitor Output
Accuracy: Within ±5 V ±0.5% (±5 V to full scale of each range)
LPF
Transfer characteristic : 2nd order Butterworth
Cutoff frequencies : 10, 30, 100, 300, 1 kHz and FLAT (6 steps)
Amplitude ratio at cutoff point : -3 ±1 dB
Attenuation : (-12 ±1) dB/oct.
HPF
Cutoff frequencies : 0.2Hz
Attenuation : Within (-6 ±1) dB/oct.
AD Converter
16 bits
TEDS
Reads information from TEDS-installed sensors.
Isolation
Between input and case (Output) : Withstand voltage 500 VDC, 1 min.
Between channels : Withstand voltage 500 VDC, 1 min.
Standard Accessories
Conversion adapter FV-2A × 4
Optional Accessories
Monitor output cable U-64 (2 m)
Note
If the transducer with a remote-sensing function, a 4-conductor
extension cable (N-81 to N-85) enables measurement.
But the remote-sensing function will be ineffective
SANTA TECHNOLOGY CO.,LTD. (Head Office)
35/218 Moo. 2, Leabkhlongsam Rd., Khlongsam, Khlongluang, Pathumthani 12120
Call 02-101-3454 ,089-006-2766
Fax 02-101-3453
Mail. [email protected]
Line : @santatech
Web : https://santatechnology.com/