Gas Detector Gas tester Gas meter Gas CO Detector gas detector CO2 Elitech LD-200
Our team will contact you with a quotation within 24 hours.
The Elitech LD-200 is designed to fit on your hand allowing you have a firm grip when detecting the leakage. The most unachievable places will be easily accessed with the LD-200
Even the small leaks
The LD-200 can detect leaks as small as 3g/yr with a very fast response (<3s) and all types of CFCs, HCFCs, HFCs, CH refrigerants. A bright backlight LCD screen and customizable alarm. Everything you need to find all leakages. This is achieved through the employment of a high sensitive heated diode sensor combined with a sophisticated microprocessor-controlled circuit.
| Sensor: | Heated Diode sensor |
| Minimum sensitivity: | 3g/yr |
| Response time: | <3s |
| Warm-up time: | <60s |
| Operating temperature: | 0℃~50℃; |
| Operating humidity: | <80%RH (non-condensing) |
|
The detector responds to all halogenated refrigerants (including Chlorine and Fluorine), which include but not limited to: CFCs e.g. R12, R11, R500, R503 etc. HCFCs e.g. R22, R123, R124, R502 etc. HFCs e.g. R134a, R404a, R410a, R407C etc. CH R600a |
SANTA TECHNOLOGY CO.,LTD. (Head Office)
35/218 Moo. 2, Leabkhlongsam Rd., Khlongsam, Khlongluang, Pathumthani 12120
Call 02-101-3454 ,089-006-2766
Fax 02-101-3453
Mail. [email protected]
Line : @santatech
Web : https://santatechnology.com/