หม้อแปลงเครื่องเชื่อม Amada miyachi welding transformer ct-110d cy-210d

SKU: Amada Miyachi
Amada Miyachi Welding Transformer CT-110D CY-210D
Availability:

1 in stock

ติดต่อขอใบเสนอราคา

ขอใบเสนอราคา

รายละเอียด

หม้อแปลงเครื่องเชื่อม Amada miyachi welding transformer ct-110d cy-210d

Model:CY-210D             CT-110D

Power requirements for welding power supply:220 / 230 / 240 / 380 / 400 / 415 / 440 / 460 / 480VAC -25% +10%, 50/60Hz

Power requirements for control power supply:100 / 120 / 220 / 230 / 240VAC +/-20%, 50/60Hz

Control method:Primary or secondary current feedback type constant current control through thyristor phase control or Power requirements fluctuation compensation control type

Timer setting:15 schedules

                                "SQUEEZE," "WELD II," "COOL II," "WELD III," "SLOPE II," "HOLD," "OFF" 00 - 99cycles

                                "SLOPE I," 0 - 9cycles

                                "WELD I" "COOL I" 0 - 9cycles         "WELD I" "COOL I" 00 - 99cycles

Pulsation count:Switching used with Off mode 0 - 9 times

Current setting range:1.0 - 80.0kA (Maximum current setting: 5.0 - 80.0kA)

Control speed:Secondary current feedback type constant current control 1/2 cycle (Requires toroidal coil)

                                Primary current feedback type constant current control 1cycle (Requires CT coil)

                                Power requirements fluctuation compensation control 1cycle

Current accuracy:For secondary current feedback type constant current control

                                        a) ±2% max. of welding power supply voltage fluctuation +10% -15%(Accuracy based on error relative to full scale.)

                                        b) ±2% max. of resistance load fluctuation ±15%(Accuracy based on error relative to full scale.)

                                        c) ±2% max. of induction load fluctuation ±15%(Accuracy based on error relative to full scale.)

Weld force output:Either 2-series control power supply voltage (1A max.) or 24VDC (0.6A max.)

Step up:2 series, 9 stages1 series, 9 stages

                        Counter 0 - 9999

                        Current increase ratio 50 - 200% of the set current in 1% step


External input signals:    
INTERLOCK/COUNT RESET (dip-switch-selectable):If a closed-contact signal is input,the system waits for the power to be turned on or the count to be reset.(For CY-210D)


                                                INTERLOCK/WELD No. SET (dip-switch-selectable):If a closed-contact signal is input, the system waits for the power to be turned on when the interlock function is selected.(For CY-110D)

External output signals: INTERLOCK/COUNT UP (dip-switch-selectable):Outputs from 2 cycles from when the power is turned on until the power is turned off, or outputs when the counter expires(contact capacity: 110 V AC, 0.5 A) (For CY-210D)


                                                INTERLOCK/WELD No. ERROR (dip-switch-selectable): Output from 2 cycles before the power is turned on until the power is turned off, or when a weld-count error occurs(contact capacity: 110 V AC, 0.5 A) (For CT-110D)

Error output:Self-diagnosis error

                                Start input error

                                Current-setting error

                                Current stepper-up ratio setting error

                                Thermostat error

                                Thyristor short-circuit error

                                No-power-supply error

                                Current upper-and-lower-limit error

                                Cond. angle error

                                Full-wave error

                                Total counter-up

                                Insufficient weld count (CY-210D Only)

                                Step-up completion

Mass :4.5kg